ENCUTGWSOFT

From VASP Wiki
Revision as of 19:32, 15 January 2017 by Karsai (talk | contribs)

ENCUTGWSOFT = [real] (energy cutoff for response function) 

Default: ENCUTGWSOFT = ENCUTGW for ALGO=ACFDT
= ENCUTGW else


The flag allows to truncate the Coulomb kernel slowly between the energy specified by ENCUTGWSOFT and ENCUTGW. This usually leads to much smoother energy-volume curves in AC-FDT and MP2 calculations. The modified Coulomb kernel is in this case: Failed to parse (Conversion error. Server ("cli") reported: "[INVALID]"): {\displaystyle v_{\bold{G}} = \frac{4 \pi e^2} {| \bold{G}|^2} \frac{1}{2} \left( 1 + {\mathbf{cos} \left( \pi \, \frac{ \frac{\hbar^{2} |\bold{G}|^2 }{2 m_e} - {{TAG|ENCUTGWSOFT}}}{ {{TAG|ENCUTGW}} - {{TAG|ENCUTGWSOFT}}} \right) \right) \qquad \mbox{for} \quad \frac{\hbar^2 |\bold{G}|^2 }{2 m_e} > {{TAG|ENCUTGWSOFT}}}

Related Tags and Sections

PRECFOCK, ENCUT, ENCUTGW, GW calculations


Contents