Pulay stress

From VASP Wiki

Band-structure calculations find the energy of a cell using a finite number of plane waves and a finite number of k-points. When comparing cells of different sizes, i.e. volume, this results in them each having different plane wave basis sets. This would be solved by using an infinite number of k-points and plane waves. In practice, a large enough plane wave energy cutoff and number of k-points leads to converged energies.[1] However, when the basis set is too small, i.e. prematurely truncated, this results in discontinuities in the total energy between cells of varying volumes. These discontinuities between energy and volume create stress that decreases the volume compared to fully converged calculations, due to the diagonal components of the stress tensor being incorrect. This is the "Pulay stress".[2] Figures 1 and 2 show these discontinuities for diamond for prematurely truncated energy cutoffs and k-point meshes, respectively, in comparison to converged curves. It may be corrected by using a few different methods in VASP.

Fig 1. Total energy vs. lattice parameter for converged and unconverged plane wave energy cutoffs. Diamond in a primitive cell - 2x2x2 k-point mesh.
Fig 2. Total energy vs. lattice parameter for converged and unconverged k-point meshes. Diamond in a primitive cell - 250 eV energy cutoff.

How to correct

The Pulay stress may be corrected in multiple ways. Generally, by calculating the relaxed structure with a larger basis set by increasing the ENCUT until convergence is reached:

  1. Set ENCUT to the default cutoff, or PREC=High in VASP.4.4. N.B. this is the lower limit.
  2. Re-run VASP with the default cutoff to obtain the final relaxed positions and cell parameters.[3]
  3. Further increase the ENCUT and repeat Steps 1 and 2, until the structure no longer changes, i.e. is converged.

One thing that is important to understand is that problems due to the Pulay stress can often be neglected if only volume conserving relaxations are performed. This is because the Pulay stress is usually almost uniform and changes the diagonal elements of the stress tensor only by a constant amount.

If volume relaxations are necessary, the following two procedures may be followed:[4]

1. Volume relaxation

One way is to very accurately relax the structure in a series of calculations on one structure:

Step 1.

Relax from the starting structure with Gaussian or Methfessel-Paxton smearing (ISMEAR = 0 or 1).

Step 2.

Copy the CONTCAR to POSCAR and relax the structure again.

Step 3.

Change the smearing method to the tetrahedron method (i.e. ISMEAR=-5) and perform a single point calculation, i.e. no relaxation of structure. These are will give highly accurate energies.

(Optional)

The previous steps should yield good energies. If there are still problems, a few more additional steps may be tried:

Step 4a.

If there are still problems, try further increasing the ENCUT.

Step 4b.

If the default energy cutoff must be used for the relaxations, then an alternative procedure may be followed. [5]

  1. Perform a single point calculation for starting structure with a higher ENCUT. In the OUTCAR file, good estimation for the Pulay stress is given as a negative pressure, e.g.:
  external pressure =    -100.29567 kB
  1. Add PSTRESS to the INCAR.
  2. Set it equal to the Pulay stress given by the 'external pressure' in the OUTCAR.

2. Equation of state fitting

An alternative way to avoid relaxing the volume is to relax the structure for a fixed set of volumes, i.e. multiple POSCAR files. These are then fitted to an equation of state[6], e.g. Murnaghan.[7] This has the advantage of also providing the bulk modulus, and we have found it may be used safely with the default energy cutoff.

The procedure is similar to the previous section. In this case, one has to do the calculations for a set of fixed volumes.[8] The following steps have to be done in these calculations:

Step 1.

Select one cell and relax it from the starting structure, keeping the volume fixed (ISIF=4; ISMEAR=0 or 1).

Step 2.

Copy the CONTCAR to POSCAR and relax the structure again (if the initial cell shape was reasonable this step can be skipped if the cell shape is kept fixed, you never have run VASP twice).

Step 3.

Change the smearing method to the tetrahedron method (i.e. ISMEAR=-5) and perform a single point calculation, i.e. no relaxation of structure. These will give highly accurate energies.

Step 4.

Repeat this for as many different volumes as desired and then fit the Energy vs. Volume curve to your chosen Equation of State.

Possible issues and advice on how to address them

It is very common among new users of plane wave codes to obtain jagged energy vs. volume plots, cf. Fig. 1 and 2. This is commonly due to two reasons:

  1. Basis set incompleteness

    The basis set is discrete and incomplete, so when the volume changes, additional plane waves are added. That causes small discontinuous changes in the energy.

    1. Use a larger plane wave cutoff, cf. Fig. 1. This is usually the preferred and simplest solution.
    2. Use more k-points, cf. Fig. 2.[9]
  2. Discontinuity of FFT grids

    Different precisions of the FFT grid defined by PREC may be used, e.g. Normal or Accurate.[10] This introduces small errors when the volume changes, as the FFT grids change discontinuously. In other words, at each volume a different FFT grid is used, causing the energy to jump discontinuously between different volumes. For more details on FFT grids, see [11].

    1. Use PREC=Accurate
    2. Increase the plane wave cutoff.
    3. Set your FFT grids manually, and choose the one that is used per default for the largest volume.

References

  1. G. P. Francis and M. C. Payne, Finite basis set corrections to total energy pseudopotential calculations, J. Condens. Matter Phys. 2, 4395 (1990).
  2. All volume/cell shape relaxation algorithms implemented in VASP work with a constant basis set. In that way, all energy changes are strictly consistent with the calculated stress tensor, and this results in an underestimation of the equilibrium volume unless a large plane wave cutoff is used. Keeping the basis set constant during relaxations also has a strange effect on the basis set. Initially, all G-vectors within a sphere are included in the basis. If the cell shape is relaxed, the direct and reciprocal lattice vectors change. This means that although the number of reciprocal G-vectors in the basis is kept fixed, the length of the G-vectors changes, indirectly changing the energy cutoff. Or to be more precise, the shape of the cutoff region changes from a sphere to an ellipsoid. Restarting VASP after a volume relaxation causes VASP to adopt a new "spherical" cutoff sphere and thus the energy changes discontinuously.
  3. The most reliable relaxed structures are obtained if the starting cell parameters are very close to the final cell parameters. If different runs yield different results, then the one run that started from the configuration, which was closest to the relaxed structure, is the most reliable one.
  4. Calculations with many plane wave codes have shown that such calculations yield reliable results for the lattice constants and the bulk modulus and other elastic properties even at relatively modest energy cutoffs. Constant energy cutoff calculations are less prone to errors caused by the basis set incompleteness than constant basis set calculations. But it should be kept in mind that volume and cell shape changes must be rather large to obtain reliable results from this method because, within the limit of very small distortions, the energy changes obtained with this method are equivalent to those obtained from the stress tensor and are therefore affected by the Pulay stress. Only volume changes of the order of 5-10 % guarantee that the errors introduced by the basis set incompleteness are averaged out.
  5. From now on all STRESS output of VASP is corrected by simply subtracting PSTRESS. In addition, all volume relaxations will take PSTRESS into account. It should be said again, use PSTRESS only if increasing the cutoff is not a viable option for some reason.
  6. The reason why this method is better than volume relaxation is that the Pulay stress is almost isotropic, and thus adds only a constant value to the diagonal elements of the stress tensor. Therefore, the relaxation for a fixed volume will yield highly accurate structures.
  7. Murnaghan Equation of State, www.wikipedia.org (2024)
  8. At first sight, this seems to be much more expensive than method number one (outlined in the previous section). But in many cases, the additional costs are only small, because the internal parameters do not change very much from volume to volume.
  9. This solves the problem because the criterion for including a plane wave in the basis set is . This means at each k-point a different basis set is used, and additional plane waves are added at each k-point at different volumes. In turn, the energy vs. volume curve becomes smoother.
  10. For PREC=Accurate, the FFT grids are chosen such that is exactly evaluated. Whereas, for PREC=Normal the FFT grids are set to 3/4 of the value that is required for an exact evaluation of .
  11. Introduction to ab-initio simulation in VASP