Template:MDCOMBINATIONS

From VASP Wiki
Revision as of 10:33, 29 May 2019 by Karsai (talk | contribs) (Created page with ":{| cellpadding="5" cellspacing="0" border="1" | ||colspan="4" style="text-align: center;"| Thermostat |- | Ensemble || Andersen...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Thermostat
Ensemble Andersen Nose-Hoover Langevin Multiple Andersen
NVE MDALGO=1 MDALGO=2 MDALGO=3 MDALGO=13
ISIF=0 ISIF=0 ISIF=0 ISIF=0
ANDERSEN_PROB=0.0 ANDERSEN_PROB=0.0
NVT MDALGO=1 MDALGO=2 MDALGO=3 MDALGO=13
ISIF=2 ISIF=2 ISIF=2 ISIF=2
NPT not available not available MDALGO=3 not available
ISIF=3