ML IWEIGHT

From VASP Wiki
Revision as of 08:50, 23 August 2021 by Karsai (talk | contribs)

ML_IWEIGHT = [integer]
Default: ML_IWEIGHT = 3 

Description: Flag to control the weighting of the energy, force and stress equations in the machine learning force field method.


For ML_IWEIGHT the following settings are possible:

  • ML_IWEIGHT=1: The unnormalized energies, forces and stress tensor training data are divided by the weights determined by the flags ML_WTOTEN (eV/atom), ML_WTIFOR (eV/Angstrom) and ML_WTSIF (kBar), respectively.
  • ML_IWEIGHT=2: The training data are normalized by using their standard deviations. The averaging is done over all training data. Then, the normalized energy, forces and stress tensor are multiplied by ML_WTOTEN, ML_WTIFOR and ML_WTSIF, respectively. In this case the flags ML_WTOTEN, ML_WTIFOR and ML_WTSIF are unitless quantities.
  • ML_IWEIGHT=3: Same as ML_IWEIGHT=2 but the training data is divided into individual subsets. For each subset the standard deviations are calculated separately. The energies, forces and stress are normalized using the average of the standard deviations of all subsets. Finally, the normalized energy, forces and stress tensor are multiplied by ML_WTOTEN, ML_WTIFOR and ML_WTSIF, respectively. The division into subsets is based on the name tag as given in the first line of the POSCAR file. If training is performed for widely different materials, for instance different phases that have widely different energies, it is important to chose different system names in the first line of the POSCAR file. If this is not done, the standard deviation for the energy might become large, concomitantly reducing the weight of the energy equations.


Mind: For ML_IWEIGHT=2 and 3 the weights are unitless quantities used to multiply the data, whereas for ML_IWEIGHT=1 they have a unit. All three methods provide unitless energies, forces and stress tensors, which are then passed to the regression. Although the defaults are usually rather sensible, it can be useful to explore different weights. For instance, if vibrational frequencies are supposed to be reproduced accurately, we found it helpful to increase ML_WTIFOR to 10-100. On the other hand, if energy difference between different phases need to be described accurately by the force field, it might be useful to increase ML_WTOTEN to around 10-100.

Related Tags and Sections

ML_LMLFF, ML_WTOTEN, ML_WTIFOR, ML_WTSIF