Revision as of 10:51, 19 April 2019
WC = [real]
Default: WC = 1000.
Description: WC specifies the weight factor for each step in Broyden mixing scheme (IMIX=4).
- WC>0
- Set all weights identical to WC (resulting in Pulay's mixing method), up to now Pulay's scheme was always superior to Broyden's 2nd method.
- WC=0
- Switch to Broyden's 2nd method, i.e., set the weight for the last step equal to 1000 and all other weights equal to 0.
- WC<0 (implemented for test purposes: not recommended)
- Try some automatic setting of the weights according to:
- in order to set small weights for the first steps and increasing weights for the last steps.
Related Tags and Sections
IMIX, INIMIX, MAXMIX, AMIX, BMIX, AMIX_MAG, BMIX_MAG, AMIN, MIXPRE