NVT ensemble: Difference between revisions
No edit summary |
No edit summary |
||
Line 4: | Line 4: | ||
The NVT ensemble is a statistical ensemble that is used to study material properties under the conditions of a | The NVT ensemble is a statistical ensemble that is used to study material properties under the conditions of a | ||
constant particle number N, constant volume V and a temperature fluctuating around an equilibrium value T. | constant particle number N, constant volume V and a temperature fluctuating around an equilibrium value T. | ||
This page describes to sample the NVT ensemble from a molecular dynamics run. | This page describes how to sample the NVT ensemble from a [[Molecular dynamics calculations|molecular dynamics]] run. | ||
== Instructions for setting up a NVT ensemble == | == Instructions for setting up a NVT ensemble == | ||
There are 4 | There are 4 choices of thermostats which can either be stochastic or deterministic to simulate the NVT ensemble. | ||
The stochastic [[Andersen thermostat]] or [[Langevin thermostat]], | |||
the deterministic [[Nose-Hoover thermostat]] or [[MDALGO#MDALGO.3D13:_Multiple_Anderson_thermostats|Multiple Anderson thermostats]] can be used. | the deterministic [[Nose-Hoover thermostat]] or [[MDALGO#MDALGO.3D13:_Multiple_Anderson_thermostats|Multiple Anderson thermostats]] can be used. | ||
See table for the corresponding {{TAG|MDALGO}} tags. | |||
{|class="wikitable" style="margin:aut | {|class="wikitable" style="margin:aut | ||
! NVT ensemble !! Andersen !! Langevin !! Nose-Hoover !! Multiple Andersen | ! NVT ensemble !! Andersen !! Langevin !! Nose-Hoover !! Multiple Andersen |
Revision as of 12:58, 19 July 2022
Category: NVT ensemble == NVT ensemble == The NVT ensemble is a statistical ensemble that is used to study material properties under the conditions of a constant particle number N, constant volume V and a temperature fluctuating around an equilibrium value T. This page describes how to sample the NVT ensemble from a molecular dynamics run. == Instructions for setting up a NVT ensemble == There are 4 choices of thermostats which can either be stochastic or deterministic to simulate the NVT ensemble. The stochastic Andersen thermostat or Langevin thermostat, the deterministic Nose-Hoover thermostat or Multiple Anderson thermostats can be used. See table for the corresponding MDALGO tags.
NVT ensemble | Andersen | Langevin | Nose-Hoover | Multiple Andersen |
---|---|---|---|---|
MDALGO | 1 | 3 | 2 | 13 |
additional tags | ANDERSEN_PROB | LANGEVIN_GAMMA | SMASS | NSUBSYS, TSUBSYS, PSUBSYS |
The user is not allowed to set ISF>2 because then the volume of the simulation would be allowed to change and the simulation would not result in a NVT ensemble. Setting ISIF=0 will speed up the calculation because the stress tensor is not computed.