Harris-Foulkes functional: Difference between revisions
No edit summary |
No edit summary |
||
Line 10: | Line 10: | ||
{{sc|Harris Foules functional|Examples|Examples that use this tag}} | {{sc|Harris Foules functional|Examples|Examples that use this tag}} | ||
---- | ---- | ||
[[Category:Electronic Minimization]][[Category:Theory]] | [[Category:Electronic Minimization]][[Category:Theory]][[Category:Exchange-correlation functionals]] |
Revision as of 08:20, 6 April 2022
The Harris-Foulkes (HF) functional is a non selfconsistent functional. The potential is constructed for some "input" charge density, then the band-structure term is calculated for this fixed non self-consistent potential. Double counting corrections are calculated from the input charge density. The functional can be written as
It is interesting that the functional gives a good description of the binding-energies, equilibrium lattice constants, and bulk-modulus even for covalently bonded systems like Ge. In a test calculation we have found that the pair-correlation function of l-Sb calculated with the HF-function and the full Kohn-Sham functional differs only slightly. Nevertheless, we must point out that the computational gain in comparison to a self-consistent calculation is in many cases very small (for Sb less than ). The main reason why to use the HF functional is therefore to access and establish the accuracy of the HF-functional, a topic which is currently widely discussed within the community of solid state physicists. To our knowledge VASP is one of the few pseudo-potential codes, which can access the validity of the HF-functional at a very basic level, i.e. without any additional restrictions like local basis-sets etc.
Within VASP the band-structure energy is exactly evaluated using the same plane-wave basis-set and the same accuracy which is used for the self-consistent calculation. The forces and the stress tensor are correct, insofar as they are an exact derivative of the Harris Foulkes functional. During a MD calculation or an ionic relaxation the charge density is correctly updated at each ionic step.