ML SION1: Difference between revisions

From VASP Wiki
No edit summary
No edit summary
Line 7: Line 7:
Test calculations showed that a 1.5 smaller value for the broadening of the radial descriptor compared to the angular descriptor (see {{TAG|ML_FF_SION2_MB}}) gives optimal results.
Test calculations showed that a 1.5 smaller value for the broadening of the radial descriptor compared to the angular descriptor (see {{TAG|ML_FF_SION2_MB}}) gives optimal results.
The default value for {{TAG|ML_FF_SION1_MB}} is chosen such that {{TAG|ML_FF_SION2_MB}} becomes 0.5.
The default value for {{TAG|ML_FF_SION1_MB}} is chosen such that {{TAG|ML_FF_SION2_MB}} becomes 0.5.
This tag is not used if {{TAG|ML_FF_IBROAD1_MB}}=1 (which is not the default).


== Related Tags and Sections ==
== Related Tags and Sections ==

Revision as of 11:42, 7 June 2021

ML_FF_SION1_MB = [real]
Default: ML_FF_SION1_MB = 0.333333 

Description: This tag specifies the width of the Gaussian functions used for broadening the atomic distributions for the radial descriptor within the machine learning force field method.


The unit of ML_FF_SION1_MB is in . Test calculations showed that a 1.5 smaller value for the broadening of the radial descriptor compared to the angular descriptor (see ML_FF_SION2_MB) gives optimal results. The default value for ML_FF_SION1_MB is chosen such that ML_FF_SION2_MB becomes 0.5.

Related Tags and Sections

ML_FF_LMLFF, ML_FF_SION2_MB, ML_FF_RCUT1_MB, ML_FF_RCUT2_MB, ML_FF_MRB1_MB, ML_FF_MRB2_MB

Examples that use this tag