CSHIFT: Difference between revisions
No edit summary |
No edit summary |
||
Line 12: | Line 12: | ||
[[The_VASP_Manual|Contents]] | [[The_VASP_Manual|Contents]] | ||
[[Category:INCAR]][[Category:Linear response]] | [[Category:INCAR]][[Category:Linear response]] [[Category:GW]] |
Revision as of 11:42, 8 March 2011
CSHIFT = [real]
Default: CSHIFT | = OMEGAMAX*1.3 / max(NOMEGA,40) | for GW calculations |
= 0.1 | for linear response calculations |
Description: CSHIFT sets the (small) complex shift η in the Kramers-Kronig transformation.
The default CSHIFT=0.1 is perfectly acceptable for most calculations and causes a slight smoothening of the real part of the dielectric function. If the gap is very small (i.e. approaching two times CSHIFT), slight inaccuracies in the static dielectric constant are possible, which can be remedied by decreasing CSHIFT. If CSHIFT is further decreased, it is strongly recommended to increase the parameter NEDOS to values around 2000.