Exercise : Determine the most stable magnetic order between the antiferromagnetic (AFM) and ferromagnetic (FM) configurations. Compare the both DOS.
- INCAR
NiO GGA AFM SYSTEM = "NiO" Electronic minimization ENCUT = 450 EDIFF = 1E-5 LORBIT = 11 LREAL = .False. ISTART = 0 NELMIN = 6 DOS ISMEAR = -5 Magnetism ISPIN = 2 MAGMOM = 2.0 -2.0 2*0 # AFM order # MAGMOM = 2.0 2.0 2*0 # FM order Mixer AMIX = 0.2 BMIX = 0.00001 AMIX_MAG = 0.8 BMIX_MAG = 0.00001
- KPOINTS
k-points 0 gamma 4 4 4 0 0 0
- POSCAR
NiO 4.17 1.0 0.5 0.5 0.5 1.0 0.5 0.5 0.5 1.0 2 2 Cartesian 0.0 0.0 0.0 1.0 1.0 1.0 0.5 0.5 0.5 1.5 1.5 1.5