NiO GGA+U: Difference between revisions
No edit summary |
No edit summary |
||
Line 61: | Line 61: | ||
1.5 1.5 1.5 | 1.5 1.5 1.5 | ||
</pre> | </pre> | ||
---- | |||
To check the results obtained with this approach, magnetic moments can be compared to those calculated with a [[NiO HSE06|hybrid]] approach. | |||
== Download == | == Download == |
Revision as of 16:41, 24 August 2016
Description: AFM NiO in the GGA+U (Dudarev's approach).
- INCAR
NiO GGA+U AFM SYSTEM = "NiO" Electronic minimization ENCUT = 300 EDIFF = 1E-4 LORBIT = 11 LREAL = .False. ISTART = 0 NELMIN = 6 DOS ISMEAR = -5 Magnetism ISPIN = 2 MAGMOM = 2.0 -2.0 2*0 Mixer AMIX = 0.2 BMIX = 0.00001 AMIX_MAG = 0.8 BMIX_MAG = 0.00001 GGA+U LDAU = .TRUE. LDAUTYPE = 2 LDAUL = 2 -1 LDAUU = 8.00 0.00 LDAUJ = 0.95 0.00 LDAUPRINT = 2 LMAXMIX = 4
- KPOINTS
k-points 0 gamma 4 4 4 0 0 0
- POSCAR
NiO 4.17 1.0 0.5 0.5 0.5 1.0 0.5 0.5 0.5 1.0 2 2 Cartesian 0.0 0.0 0.0 1.0 1.0 1.0 0.5 0.5 0.5 1.5 1.5 1.5
To check the results obtained with this approach, magnetic moments can be compared to those calculated with a hybrid approach.
Download
To the list of examples or to the main page