NVT ensemble: Difference between revisions

From VASP Wiki
No edit summary
No edit summary
Line 20: Line 20:
The additional tags in the column for every thermostat have to be set. For example the [[Nose-Hoover thermostat]] needs the additional {{TAG|SMASS}} tag. There are two implementations of the [[Nose-Hoover thermostat]] in VASP which will give the same results. The {{TAG|MDALGO}}=0 version can be used even if the code was compiled without the precompiler option [[Precompiler_options#-Dtbdyn|-Dtbdyn]].
The additional tags in the column for every thermostat have to be set. For example the [[Nose-Hoover thermostat]] needs the additional {{TAG|SMASS}} tag. There are two implementations of the [[Nose-Hoover thermostat]] in VASP which will give the same results. The {{TAG|MDALGO}}=0 version can be used even if the code was compiled without the precompiler option [[Precompiler_options#-Dtbdyn|-Dtbdyn]].
To enforce constant volume throughout the calculation, {{TAG|ISIF}} has to be set to less than 3. The cell shape and volume have
To enforce constant volume throughout the calculation, {{TAG|ISIF}} has to be set to less than 3. The cell shape and volume have
to be preoptimized when doing NVT simulations. This can either be done with a [[NpT_ensemble|NPT]] molecular-dynamics run or by doing static optimization calculations with {{TAG|IBRION}}=1 or 2 and setting {{TAG|ISIF}} larger than 2.
to be preoptimized when doing NVT simulations. This can either be done with a [[NpT_ensemble|NPT]] molecular-dynamics run or by doing static optimization calculations with {{TAG|IBRION}}=1 or 2 and setting {{TAG|ISIF}}>2.


Other tags related to molecular dynamics simulations can be found [[Molecular dynamics calculations|here]].  
Other tags related to molecular dynamics simulations can be found [[Molecular dynamics calculations|here]].  

Revision as of 10:34, 20 July 2022

The NVT ensemble is a statistical ensemble that is used to study material properties under the conditions of a constant particle number N, constant volume V and a temperature fluctuating around an equilibrium value T. This page describes how to sample the NVT ensemble from a molecular dynamics run.

Instructions for setting up a NVT ensemble

There are four choices of thermostats which can either be stochastic or deterministic to simulate the NVT ensemble. The stochastic Andersen thermostat or Langevin thermostat, the deterministic Nose-Hoover thermostat or Multiple Andersen thermostats can be used. See table for the corresponding MDALGO tags.

NVT ensemble Andersen Langevin Nose-Hoover Multiple Andersen
MDALGO 1 3 0 or 2 13
additional tags to set ANDERSEN_PROB LANGEVIN_GAMMA SMASS NSUBSYS, TSUBSYS, PSUBSYS

The additional tags in the column for every thermostat have to be set. For example the Nose-Hoover thermostat needs the additional SMASS tag. There are two implementations of the Nose-Hoover thermostat in VASP which will give the same results. The MDALGO=0 version can be used even if the code was compiled without the precompiler option -Dtbdyn. To enforce constant volume throughout the calculation, ISIF has to be set to less than 3. The cell shape and volume have to be preoptimized when doing NVT simulations. This can either be done with a NPT molecular-dynamics run or by doing static optimization calculations with IBRION=1 or 2 and setting ISIF>2.

Other tags related to molecular dynamics simulations can be found here.

An example INCAR file for the Langevin thermostat could look like

 #INCAR molecular dynamics tags NVT ensemble 
 IBRION = 0                   # choose molecular dynamics 
 MDALGO = 3                   # using Langevin thermostat 
 ISIF = 2                     # compute stress tensor but do not change box volume/shape 
 TEBEG = 300                  # set temperature 
 NSW = 10000                  # number of time steps 
 POTIM = 1.0                  # time step in femto seconds 
 LANGEVIN_GAMMA = 10.0   10.0 # setting friction coefficient in inverse time units for two atom types


Mind: This INCAR file only contains the parameters for the molecular dynamics part. The electronic minimization or the machine learning tags have to be added.


Related tags and articles

REPORT, Molecular dynamics calculations