Line 6: Line 6:
The KS kinetic-energy density <math>\tau_{\sigma}</math> should in principle be larger than the von Weizsäcker kinetic-energy density <math>\tau_{\sigma}^{\textrm{W}}=\left\vert\nabla\rho_{\sigma}\right\vert^{2}/\left(8\rho_{\sigma}\right)</math>. However, for numerical reasons this may not always be the case and can potentially lead to problems depending on the meta-GGA. If {{TAG|LTBOUNDLIBXC}}=.TRUE. in {{FILE|INCAR}}, then <math>\tau_{\sigma}=\max(\tau_{\sigma},\tau_{\sigma}^{\mathrm{W}})</math> is applied before <math>\tau_{\sigma}</math> is used in a meta-GGA functional from Libxc.
The KS kinetic-energy density <math>\tau_{\sigma}</math> should in principle be larger than the von Weizsäcker kinetic-energy density <math>\tau_{\sigma}^{\textrm{W}}=\left\vert\nabla\rho_{\sigma}\right\vert^{2}/\left(8\rho_{\sigma}\right)</math>. However, for numerical reasons this may not always be the case and can potentially lead to problems depending on the meta-GGA. If {{TAG|LTBOUNDLIBXC}}=.TRUE. in {{FILE|INCAR}}, then <math>\tau_{\sigma}=\max(\tau_{\sigma},\tau_{\sigma}^{\mathrm{W}})</math> is applied before <math>\tau_{\sigma}</math> is used in a meta-GGA functional from Libxc.


However, according to tests, for some of the most common meta-GGA functionals like SCAN{{cite|sun:prl:15}}, a violation of the lower bound is technically not a problem and, furthermore, applying <math>\tau_{\sigma}=\max(\tau_{\sigma},\tau_{\sigma}^{\mathrm{W}})</math> leads to very inaccurate forces and stress tensor. Therefore, by default {{TAG|LTBOUNDLIBXC}}=.FALSE..
However, according to tests, for some of the most common meta-GGA functionals like SCAN{{cite|sun:prl:15}}, a violation of the lower bound is technically not a problem and, furthermore, applying <math>\tau_{\sigma}=\max(\tau_{\sigma},\tau_{\sigma}^{\mathrm{W}})</math> leads to very inaccurate forces and stress tensor. Therefore, by default {{TAG|LTBOUNDLIBXC}}=.FALSE. and Libxc should be compiled  with the option <code>--disable-fhc</code> has explained [[Makefile.include#Libxc_.28optional.29|here]].


== Related Tags and Sections ==
== Related Tags and Sections ==

Revision as of 20:34, 20 January 2022

LTBOUNDLIBXC = .TRUE. | .FALSE.
Default: LTBOUNDLIBXC = .FALSE. 

Description: LTBOUNDLIBXC specifies whether or not the lower bound for the Kohn-Sham kinetic-energy density () is enforced before is used in a meta-GGA functional from Libxc.


The KS kinetic-energy density should in principle be larger than the von Weizsäcker kinetic-energy density . However, for numerical reasons this may not always be the case and can potentially lead to problems depending on the meta-GGA. If LTBOUNDLIBXC=.TRUE. in INCAR, then is applied before is used in a meta-GGA functional from Libxc.

However, according to tests, for some of the most common meta-GGA functionals like SCAN[1], a violation of the lower bound is technically not a problem and, furthermore, applying leads to very inaccurate forces and stress tensor. Therefore, by default LTBOUNDLIBXC=.FALSE. and Libxc should be compiled with the option --disable-fhc has explained here.

Related Tags and Sections

LIBXC1, LIBXC2, METAGGA


Examples that use this tag

References