Practical considerations for transition state finding calculations: Difference between revisions
No edit summary |
|||
(27 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
This page details a few practical considerations for obtaining accurate and reliable transition state energies using the Nudged Elastic Band (NEB) and | This page details a few practical considerations for obtaining accurate and reliable transition state energies using the [[Nudged elastic bands|Nudged Elastic Band]] (NEB){{cite|mills:surf-sci:1995}}{{cite|jonsson:book:1998}} and [[IRC calculations | Intrinsic Reaction Coordinate]] (IRC) {{Cite|hratchian:jpc:2002}} methods implemented in VASP. | ||
We list a few common issues encountered when running calculations with the NEB and IRC methods and identify possible solutions. | |||
== NEB | == NEB calculations == | ||
=== Restart with a better guess for the initial and final state configurations === | === Restart with a better guess for the initial and final state configurations === | ||
'''Problem''': While performing an NEB calculation, | [[File:example_neb_negative_energies.png|200px|thumb|right|An example band which shows intermediate structures with lower energy than the initial and final configurations.]] | ||
'''Problem''': While performing an NEB calculation, there might be points on the band which have lower energy than that of the initial and final state configurations (corresponding to the structures that were placed in the 00 and 0x, where x is the number of {{TAG|IMAGES}} plus one). The figure on the right shows an example where the red (computed) points of the intermediate images are more stable than the initial and final configurations. The presence of these intermediate states is not an issue for the NEB methodology. However, if we are seeking to understand elementary reaction steps of one reaction event each, then we would like to have a band consisting of only one maxima and two minima (consisting of the initial and final states). | |||
'''Possible solutions''' | '''Possible solutions''' | ||
* Relax the configurations with lower energy. These structures would then correspond to new initial and final configurations. Restart the NEB with these new configurations as the endpoints of the band. | * Relax the configurations with lower energy. These structures would then correspond to new initial and final configurations. Restart the NEB with these new configurations as the endpoints of the band. | ||
* Make sure that the NEB was run with sufficient (and commensurate to the initial and final structures) accuracy. An important requirement is a small enough {{TAG|EDIFF}}, which governs the accuracy of the forces used in the NEB method. | * Make sure that the NEB was run with sufficient (and commensurate to the initial and final structures) accuracy. An important requirement is a small enough {{TAG|EDIFF}}, which governs the accuracy of the forces used in the NEB method. | ||
=== Band becomes "floppy" === | === Band becomes "floppy" === | ||
'''Problem''' The band between the {{TAG|IMAGES}} of the NEB calculation is non-monotonic and appears "floppy". | '''Problem''' The band between the {{TAG|IMAGES}} of the NEB calculation is non-monotonic and appears "floppy". | ||
In such a scenario the interpolated band is likely to oscillate between the computed points. | |||
This problem typically appears when one or more images are added to an already computed band. | This problem typically appears when one or more images are added to an already computed band. | ||
Line 21: | Line 22: | ||
* This problem is likely caused by the value of {{TAG|SPRING}} being too small. | * This problem is likely caused by the value of {{TAG|SPRING}} being too small. | ||
* Check if {{TAG|EDIFF}} is accurate enough for computation of the forces. | * Check if {{TAG|EDIFF}} is accurate enough for computation of the forces. | ||
* Check the interpolation algorithm that you use to determine the interpolated band. A cubic spline might suffice in most cases. | |||
=== Band does not converge === | === Band does not converge === | ||
Line 37: | Line 39: | ||
* Check if there is exactly one imaginary mode by computing the second derivatives of the energy as implemented in {{TAG|IBRION}}. | * Check if there is exactly one imaginary mode by computing the second derivatives of the energy as implemented in {{TAG|IBRION}}. | ||
== IRC | == IRC calculations == | ||
'''Problem''' Unrealistic structures are generated along the IRC path | '''Problem''' Unrealistic structures are generated along the IRC path | ||
Line 44: | Line 46: | ||
* Make sure that a very tight force convergence criteria has been used to determine the transition state; {{TAG|EDIFFG}} must be at most -0.025. | * Make sure that a very tight force convergence criteria has been used to determine the transition state; {{TAG|EDIFFG}} must be at most -0.025. | ||
* Choose a smaller value of {{TAG|IRC_VNORM0}} so that the path conforms with the intrinsic reaction coordinate more closely. | * Choose a smaller value of {{TAG|IRC_VNORM0}} so that the path conforms with the intrinsic reaction coordinate more closely. | ||
== Related articles == | |||
[[Nudged elastic bands|Nudged elastic bands]], | |||
[[IRC calculations]] | |||
== References == | |||
<references/> | |||
[[Category:Howto]][[Category:Transition States]] |
Latest revision as of 13:07, 16 October 2024
This page details a few practical considerations for obtaining accurate and reliable transition state energies using the Nudged Elastic Band (NEB)[1][2] and Intrinsic Reaction Coordinate (IRC) [3] methods implemented in VASP. We list a few common issues encountered when running calculations with the NEB and IRC methods and identify possible solutions.
NEB calculations
Restart with a better guess for the initial and final state configurations
Problem: While performing an NEB calculation, there might be points on the band which have lower energy than that of the initial and final state configurations (corresponding to the structures that were placed in the 00 and 0x, where x is the number of IMAGES plus one). The figure on the right shows an example where the red (computed) points of the intermediate images are more stable than the initial and final configurations. The presence of these intermediate states is not an issue for the NEB methodology. However, if we are seeking to understand elementary reaction steps of one reaction event each, then we would like to have a band consisting of only one maxima and two minima (consisting of the initial and final states).
Possible solutions
- Relax the configurations with lower energy. These structures would then correspond to new initial and final configurations. Restart the NEB with these new configurations as the endpoints of the band.
- Make sure that the NEB was run with sufficient (and commensurate to the initial and final structures) accuracy. An important requirement is a small enough EDIFF, which governs the accuracy of the forces used in the NEB method.
Band becomes "floppy"
Problem The band between the IMAGES of the NEB calculation is non-monotonic and appears "floppy". In such a scenario the interpolated band is likely to oscillate between the computed points. This problem typically appears when one or more images are added to an already computed band.
Possible solutions
- This problem is likely caused by the value of SPRING being too small.
- Check if EDIFF is accurate enough for computation of the forces.
- Check the interpolation algorithm that you use to determine the interpolated band. A cubic spline might suffice in most cases.
Band does not converge
Problem The calculation does not converge, i.e., the NEB method does not find a reasonable path between an initial and final state configuration. Sometimes a completely different path is found than the desired path.
Possible solutions
- Choose a different interpolation strategy to generate your initial guessed path
- Try the Improved dimer method instead
- Check if the numbering of the atoms is the initial and final configurations. Different ordering of atoms will lead to an unexpected path. Visualizing the initial interpolated path should help with diagnosing any issues related to incorrectly ordered atoms.
Checking convergence
Problem Unsure if the highest energy point in the NEB is the first order saddle point between the initial and final state configurations
Possible solutions
- Check if there is exactly one imaginary mode by computing the second derivatives of the energy as implemented in IBRION.
IRC calculations
Problem Unrealistic structures are generated along the IRC path
Possible solution
- Make sure that a very tight force convergence criteria has been used to determine the transition state; EDIFFG must be at most -0.025.
- Choose a smaller value of IRC_VNORM0 so that the path conforms with the intrinsic reaction coordinate more closely.
Related articles
Nudged elastic bands, IRC calculations
References
- ↑ G. Mills, H. Jonsson and G. K. Schenter, Reversible work transition state theory: application to dissociative adsorption of hydrogen, Surf. Sci., 324, 305 (1995).
- ↑ H. Jonsson, G. Mills and K. W. Jacobsen, Nudged Elastic Band Method for Finding Minimum Energy Paths of Transitions, in Classical and Quantum Dynamics in Condensed Phase Simulations, ed. B. J. Berne, G. Ciccotti and D. F. Coker (World Scientific, 1998).
- ↑ H. P. Hratchian and H. B. Schlegel, Following Reaction Pathways Using a Damped Classical Trajectory Algorithm, J. Phys. Chem. A 106, 165 (2002).