HFSCREEN: Difference between revisions
No edit summary |
No edit summary |
||
(34 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
{{TAGDEF|HFSCREEN|[real]|none}} | {{TAGDEF|HFSCREEN|[real]|0 (none)}} | ||
Description: {{TAG|HFSCREEN}} specifies the range-separation parameter in [[ | Description: {{TAG|HFSCREEN}} (in Å<sup>-1</sup>) specifies the range-separation parameter in [[Hybrid functionals: formalism|range-separated hybrid functionals]]. | ||
---- | ---- | ||
In case {{TAG|LHFCALC}}=.TRUE., in combination with PBE potentials (or {{TAG|GGA}}=PE), attributing a value to {{TAG|HFSCREEN}} will switch from the PBE0 functional to e.g., the closely related HSE03 or [[ | In case {{TAG|LHFCALC}}=.TRUE., in combination with PBE potentials (or {{TAG|GGA}}=PE), attributing a value to {{TAG|HFSCREEN}} will switch from the PBE0 functional to, e.g., the closely related [[list_of_hybrid_functionals#HSE03|HSE03]] ({{TAG|HFSCREEN}}=0.3) or [[list_of_hybrid_functionals#HSE06|HSE06]] ({{TAG|HFSCREEN}}=0.2) functionals. It also needs to be set for dielectric-dependent hybrid functionals (DDH) and doubly screened hybrid (DSH) functionals, see {{TAG|LMODELHF}}. | ||
== Related | == Related tags and articles == | ||
{{TAG|LMODELHF}}, | |||
{{TAG|AEXX}}, | {{TAG|AEXX}}, | ||
{{TAG|ALDAX}}, | |||
{{TAG|ALDAC}}, | |||
{{TAG|AGGAX}}, | {{TAG|AGGAX}}, | ||
{{TAG|AGGAC}}, | {{TAG|AGGAC}}, | ||
{{TAG| | {{TAG|LTHOMAS}}, | ||
{{TAG|LRHFCALC}}, | |||
[[ | [[list_of_hybrid_functionals|List of hybrid functionals]], | ||
[[ | [[Hybrid_functionals:_formalism|Hybrid functionals: formalism]] | ||
{{sc|HFSCREEN|Examples|Examples that use this tag}} | |||
[[Category:INCAR]][[Category: | [[Category:INCAR tag]][[Category:Exchange-correlation functionals]][[Category:Hybrid_functionals]] |
Latest revision as of 07:28, 23 May 2024
HFSCREEN = [real]
Default: HFSCREEN = 0 (none)
Description: HFSCREEN (in Å-1) specifies the range-separation parameter in range-separated hybrid functionals.
In case LHFCALC=.TRUE., in combination with PBE potentials (or GGA=PE), attributing a value to HFSCREEN will switch from the PBE0 functional to, e.g., the closely related HSE03 (HFSCREEN=0.3) or HSE06 (HFSCREEN=0.2) functionals. It also needs to be set for dielectric-dependent hybrid functionals (DDH) and doubly screened hybrid (DSH) functionals, see LMODELHF.
Related tags and articles
LMODELHF, AEXX, ALDAX, ALDAC, AGGAX, AGGAC, LTHOMAS, LRHFCALC, List of hybrid functionals, Hybrid functionals: formalism