NVT ensemble: Difference between revisions

From VASP Wiki
No edit summary
No edit summary
 
(54 intermediate revisions by 3 users not shown)
Line 1: Line 1:
[[:Category: NVT ensemble]]
The [[NVT ensemble]] (canonical ensemble) is a [[:Category:Ensembles|statistical ensemble]] that is used to study material properties under the conditions of a 
constant particle number N, constant volume V and a temperature fluctuating around an equilibrium value <math>\langle T \rangle</math>.
This page describes how to sample the NVT ensemble from a [[Molecular dynamics calculations|molecular-dynamics]] run. 
''' Instructions for setting up an NVT ensemble '''


== NVT ensemble ==
There are four choices of thermostats to control the temperature for the NVT ensemble
The NVT ensemble is a statistical ensemble that is used to study properties under the conditions of a
The stochastic [[Andersen thermostat]] and [[Langevin thermostat]], as well as
constant particle number N, constant volume V and a temperature fluctuating around an equilibrium value T.
the deterministic [[Nose-Hoover thermostat]] and [[MDALGO#MDALGO.3D13:_Multiple_Anderson_thermostats|Multiple Andersen thermostats]] can be used.  
The ensemble ca be sampled with molecular dynamics simulations.            
See table for the corresponding {{TAG|MDALGO}} setting and related tags.  


== Instructions for setting up a NVT ensemble ==
{|class="wikitable" style="margin:aut
There are 4 possibilities to simulate the NVT ensemble. The stochastic Andersen or Langevin thermostat,
! NVT ensemble !! Andersen !! Langevin !! Nose-Hoover !! Multiple Andersen 
the deterministic Nose-Hoover thermostat or multiple Andersen thermostats can be used.
|-
|{{TAG|MDALGO}}          ||  style="text-align:center;"|  1        ||  style="text-align:center;"|  3            ||  style="text-align:center;"|    0 or 2      ||  style="text-align:center;"|      13
|- {{TAG|PSUBSYS}}
| additional tags to set || style="text-align:center;"| {{TAG|ANDERSEN_PROB}} || style="text-align:center;"|  {{TAG|LANGEVIN_GAMMA}} || style="text-align:center;"| {{TAG|SMASS}}      || style="text-align:center;"|  {{TAG|NSUBSYS}}, {{TAG|TSUBSYS}}, {{TAG|PSUBSYS}}
|}


{|class="wikitable" style="margin:aut
The additional tags in the column for every thermostat have to be set. For example, the [[Nose-Hoover thermostat]] needs the additional {{TAG|SMASS}} tag. There are two implementations of the [[Nose-Hoover thermostat]] in VASP which will give the same results. The {{TAG|MDALGO}}=0 version can be used even if the code was compiled without the precompiler option [[Precompiler_options#-Dtbdyn|-Dtbdyn]].
! NVT ensemble !! Andersen !! Langevin !! Nose-Hoover !! Multiple Andersen
To enforce constant volume throughout the calculation, {{TAG|ISIF}} has to be set to less than three. The cell shape and volume have
|-
to be preoptimized when doing NVT simulations. This can either be done with a [[NpT_ensemble|NpT]] [[Molecular dynamics calculations|molecular-dynamics]] run or by performing structure and volume optimization with {{TAG|IBRION}}=1 or 2 and setting {{TAG|ISIF}}>2.
|MDALGO           ||     1       ||     3            ||     2      ||       13
A general guide for molecular-dynamics simulations can be found on the [[Molecular dynamics calculations|molecular-dynamics]] page.
|-
 
| additional tags || {{TAG|ANDERSEN_PROB}} ||   {{TAG|LANGEVIN_GAMMA}} ||  {{TAG|SMASS}}     || {{TAG|NSUBSYS}}, {{TAG|TSUBSYS}}, {{TAG|PSUBSYS}}
''Example {{FILE|INCAR}} file for the [[Nose-Hoover thermostat]]''
|}
 
  #INCAR molecular-dynamics tags NVT ensemble
  {{TAGBL|IBRION}} = 0                  # choose molecular dynamics
  {{TAGBL|MDALGO}} = 2                  # using Langevin thermostat
  {{TAGBL|ISIF}} = 2                    # compute stress tensor but do not change box volume/shape
  {{TAGBL|TEBEG}} = 300                  # set temperature
  {{TAGBL|NSW}} = 10000                  # number of time steps
  {{TAGBL|POTIM}} = 1.0                  # time step in femto seconds
  {{TAGBL|SMASS}} = 1.0                  # setting the virtual mass for the Nose-Hoover thermostat
{{NB|mind| This {{FILE|INCAR}} file only contains the parameters for the molecular-dynamics part. The [[Electronic minimization|electronic minimization]] or the [[Machine-learned force fields|machine learning]] tags have to be added.}}
 
==Related tags and articles==
[[Molecular dynamics calculations|Molecular-dynamics calculations]], {{TAG|ISIF}}, {{TAG|MDALGO}}, {{TAG|ISIF}}, {{TAG|MDALGO}}, {{TAG|LANGEVIN_GAMMA}}, {{TAG|SMASS}},{{TAG|ANDERSEN_PROB}}, {{TAG|NSUBSYS}}, {{TAG|TSUBSYS}}, {{TAG|PSUBSYS}}


The user is not allowed to set ISF>2 because then the volume of the simulation would be allowed to change
[[Category:Molecular dynamics]][[Category:Ensembles]][[Category:Thermostats]]
and the simulation would not result in a NVT ensemble.

Latest revision as of 11:45, 24 April 2023

The NVT ensemble (canonical ensemble) is a statistical ensemble that is used to study material properties under the conditions of a constant particle number N, constant volume V and a temperature fluctuating around an equilibrium value . This page describes how to sample the NVT ensemble from a molecular-dynamics run.

Instructions for setting up an NVT ensemble

There are four choices of thermostats to control the temperature for the NVT ensemble: The stochastic Andersen thermostat and Langevin thermostat, as well as the deterministic Nose-Hoover thermostat and Multiple Andersen thermostats can be used. See table for the corresponding MDALGO setting and related tags.

NVT ensemble Andersen Langevin Nose-Hoover Multiple Andersen
MDALGO 1 3 0 or 2 13
additional tags to set ANDERSEN_PROB LANGEVIN_GAMMA SMASS NSUBSYS, TSUBSYS, PSUBSYS

The additional tags in the column for every thermostat have to be set. For example, the Nose-Hoover thermostat needs the additional SMASS tag. There are two implementations of the Nose-Hoover thermostat in VASP which will give the same results. The MDALGO=0 version can be used even if the code was compiled without the precompiler option -Dtbdyn. To enforce constant volume throughout the calculation, ISIF has to be set to less than three. The cell shape and volume have to be preoptimized when doing NVT simulations. This can either be done with a NpT molecular-dynamics run or by performing structure and volume optimization with IBRION=1 or 2 and setting ISIF>2. A general guide for molecular-dynamics simulations can be found on the molecular-dynamics page.

Example INCAR file for the Nose-Hoover thermostat

 #INCAR molecular-dynamics tags NVT ensemble 
 IBRION = 0                   # choose molecular dynamics 
 MDALGO = 2                   # using Langevin thermostat 
 ISIF = 2                     # compute stress tensor but do not change box volume/shape 
 TEBEG = 300                  # set temperature 
 NSW = 10000                  # number of time steps 
 POTIM = 1.0                  # time step in femto seconds 
 SMASS = 1.0                  # setting the virtual mass for the Nose-Hoover thermostat
Mind: This INCAR file only contains the parameters for the molecular-dynamics part. The electronic minimization or the machine learning tags have to be added.

Related tags and articles

Molecular-dynamics calculations, ISIF, MDALGO, ISIF, MDALGO, LANGEVIN_GAMMA, SMASS,ANDERSEN_PROB, NSUBSYS, TSUBSYS, PSUBSYS