{{TAGDEF| | {{TAGDEF|LTBOUNDLIBXC|.TRUE. {{!}} .FALSE. |.FALSE.}} | ||
Description: {{TAG| | Description: {{TAG|LTBOUNDLIBXC}} specifies whether or not the lower bound for the Kohn-Sham kinetic-energy density <math>\tau_{\sigma}</math> (<math>\tau_{\sigma}^{\textrm{W}}<\tau_{\sigma}</math>) is enforced before <math>\tau_{\sigma}</math> is used in a {{TAG|METAGGA}} functional from Libxc. | ||
---- | ---- | ||
The Kohn-Sham kinetic-energy density | |||
:<math>\tau_{\sigma}=\frac{1}{2}\sum_{i}\nabla\psi_{i\sigma}^{*}\cdot\nabla\psi_{i\sigma}</math> | |||
should, in principle, be larger than the von Weizsäcker kinetic-energy density{{cite|kurth:ijqc:1999}} | |||
:<math>\tau_{\sigma}^{\textrm{W}}=\frac{\left\vert\nabla n_{\sigma}\right\vert^{2}}{8 n_{\sigma}}.</math> | |||
However, for numerical reasons this may not always be the case and can potentially lead to problems depending on the meta-GGA. If {{TAG|LTBOUNDLIBXC}}=.TRUE. in {{FILE|INCAR}}, then <math>\tau_{\sigma}=\max(\tau_{\sigma},\tau_{\sigma}^{\mathrm{W}})</math> is applied before <math>\tau_{\sigma}</math> is used in a meta-GGA functional from Libxc. | |||
However, according to tests, for some of the most common meta-GGA functionals like SCAN{{cite|sun:prl:15}}, a violation of the lower bound is technically not a problem and, furthermore, applying <math>\tau_{\sigma}=\max(\tau_{\sigma},\tau_{\sigma}^{\mathrm{W}})</math> leads to very inaccurate forces and stress tensor. Therefore, by default {{TAG|LTBOUNDLIBXC}}=.FALSE. and Libxc should be compiled with the option <code>--disable-fhc</code> has explained [[Makefile.include#Libxc_.28optional.29|here]]. | |||
== Related tags and articles == | |||
{{TAG|LIBXC1}}, | |||
{{TAG|LIBXC2}}, | |||
{{TAG|METAGGA}} | |||
{{sc|LTBOUNDLIBXC|Examples|Examples that use this tag}} | |||
== References == | |||
<references/> | |||
---- | |||
[[Category:INCAR tag]][[Category:Exchange-correlation functionals]][[Category:meta-GGA]] |
Latest revision as of 07:10, 12 June 2024
LTBOUNDLIBXC = .TRUE. | .FALSE.
Default: LTBOUNDLIBXC = .FALSE.
Description: LTBOUNDLIBXC specifies whether or not the lower bound for the Kohn-Sham kinetic-energy density () is enforced before is used in a METAGGA functional from Libxc.
The Kohn-Sham kinetic-energy density
should, in principle, be larger than the von Weizsäcker kinetic-energy density[1]
However, for numerical reasons this may not always be the case and can potentially lead to problems depending on the meta-GGA. If LTBOUNDLIBXC=.TRUE. in INCAR, then is applied before is used in a meta-GGA functional from Libxc.
However, according to tests, for some of the most common meta-GGA functionals like SCAN[2], a violation of the lower bound is technically not a problem and, furthermore, applying leads to very inaccurate forces and stress tensor. Therefore, by default LTBOUNDLIBXC=.FALSE. and Libxc should be compiled with the option --disable-fhc
has explained here.